- UPS works for a very short time when switching to battery power during a power outage.
- The UPS shuts off the computer (or load) immediately after power is lost in the office or home.
- The computer does not turn on (no power from the UPS), and the red light with a battery symbol is on the UPS.
- The computer does not turn on (no power from the UPS), and no lights are on the UPS with no signs of functionality.
These symptoms indicate that your UPS (Uninterruptible Power Supply) requires repair. Based on the most common user queries, after contacting our service center located in Almaty, we perform a free diagnostic and inform you of the cause of the issue.
There are two main types of faults requiring repair:
- Faulty battery or multiple batteries, depending on the power capacity of the UPS. We use a certified battery testing device, “KULON-12T,” to check battery capacity and functionality. If the capacity is reduced by more than 30-40% from new battery levels, we recommend repair, which involves battery replacement.
- Faulty UPS control board, requiring repair. The most common faults with the board occur in UPS models from brands such as APC (American Power Conversion), IPPON, EATON, SVC, and TrippLite. Problems may arise in both the battery charging circuits and the input circuits due to issues with the incoming power supply. We stock a wide range of boards and components from decommissioned UPS units, and we can source replacements if needed.
For repairs, we exclusively use original new batteries. The production date of the batteries is also crucial; we use batteries no older than six months before installation. We have been working with one battery supplier for over 7 years. Repairs are performed at the component level, and when necessary, we replace microchips, high-voltage transistors, and other elements.
Working with our service center in Almaty will bring you a positive experience, and we hope for long-term cooperation. You can find information about our other services on other pages of our website.
UPS Repair Services:
- UPS not turning on.
- Battery replacement in UPS.
- UPS not functioning after power is disconnected.
- UPS can't handle the load.
- No output voltage from the UPS.
- Battery indicator blinking on UPS.
- APC UPS repair (or another well-known brand).
- Battery replacement in UPS.
- UPS not switching to battery during power outage.
- UPS needs servicing.
- UPS not holding a charge.
PRICE LIST FOR DATA RECOVERY SERVICES
Service Name | Average Cost of Solution |
Initial UPS Diagnosis | Free (if further repair is required) |
Battery Replacement (service) | Included in the cost of batteries |
Battery Replacement (one unit) 12V 7Ah, Original Ritar or equivalent | From 10000 KZT |
Battery Replacement (one unit) 12V 9Ah, Original Ritar or equivalent | From 15000 KZT |
Battery Replacement (one unit) 12V 12Ah, Original Ritar or equivalent | From 18000 KZT |
Battery Replacement (one unit) 12V 18Ah, Original Ritar or equivalent | From 25000 KZT |